| Self-regulation of GFB valves |
Many other manufacturers of diverter or blow-off valves offer different spring kits for different boost levels. These are not needed with any GFB valve, because they are self-regulating valves. This means the valves can be used regardless of the boost pressure, without any modifications or adjustments to the valve.
This is achieved by having the same boost pressure acting both behind and in front of the piston (on the pressure side). Inside the piston, however, it can act on an area approx. 25% larger than on the underside of the piston, which means the force from above is also greater than from below. In this way the piston stays closed under load, no matter how much boost is applied.
Every GFB valve nevertheless has a spring inside. Unlike with other manufacturers, however, this spring is not there to keep the valve closed under load; instead it allows the opening time of the valve on throttle lift-off (e.g. during gear changes) to be adjusted. This way the valve can be set so that the optimum "amount" of pressure stays in the charge-air system during the gear change – just enough that no compressor surge occurs (the turbo being slowed down by the back pressure when the throttle closes on lift-off) and the turbocharger does not have to rebuild working pressure in the charge-air system as soon as you get back on the throttle. Correct adjustment gives noticeably better response than OEM valves, because these always open "fully" and so vent too much air from the charge-air system, which means the turbocharger first has to refill the system when you get back on the throttle. The piston spring preload does, however, need to be adjusted after installation. How this works is described in a separate article. |
| Electronically vs. pressure-controlled valves |
There are now two technologies for controlling diverter valves. For decades, turbocharged petrol engines used pressure-controlled valves. You can recognise these by the approx. 3 mm control line, which usually enters the valve from the top.
Since around 2005, VAG and several other car manufacturers have fitted an electronically controlled diverter valve, which brings clear advantages. Above all, the actuation (i.e. opening and closing the valve) can be done much faster electronically, which all but eliminates compressor surge and also improves response. |
| Running the DV+ without the main piston spring |
The DV+ valves have two springs: a thin spring that fits over the metal pin of the control unit (this must ALWAYS be fitted!) and the main piston spring, which sits directly behind the piston. This one can be fitted, but does not have to be.
The main piston spring is there to improve response. When an OEM valve opens, it always opens fully, i.e. too much pressure is vented, which has to be built up again when you get back on the throttle before the car picks up full speed again. The spring behind the piston, however, ensures that only enough air is vented on throttle lift-off to "just" prevent compressor surge, i.e. the optimum pressure is held in the system, which significantly improves response and throttle pick-up.
Alternatively, this spring can also be left out. The DV+ then works exactly like the OEM valve, i.e. it always opens "fully".
Leaving out the spring on VAG DSG vehicles
There is a persistent rumour that the main piston spring should be left out on cars with a DSG gearbox. This is expressly NOT the case. Here too the spring improves response, even though the DSG shifts very quickly and the pressure loss in the system is therefore not as great as with a manual gearbox. |
| Advantages of the DV+ over the OEM valve |
VAG has used several different versions of OEM valves over the years:
-
Diaphragm valves fitted to the Golf 5
The diaphragm valves are known for failing frequently, especially on tuned vehicles. The diaphragm very often tears because of the higher boost pressure and the higher temperatures that occur on remapped cars.

-
OEM valve with plastic piston from the Golf 6 onwards
Even brand-new OEM valves with plastic pistons leak (and more than you might think!) – this is not a symptom of wear but of the design! What’s more, they do not always close reliably after a gear change at high revs.

The OEM plastic-piston valves already leak from 0.3 bar and become increasingly "leaky" as the mileage goes up, so the car gradually loses more and more power. This leads to greater wear on the turbocharger, as the leaking system means it has to spin faster to deliver the required pressure.
Here is a photo on our "test bench" of a brand-new OEM valve (VAG part no. ending in "D") with a plastic piston at just 0.3 bar:

And here is a photo of the same setup with a GFB DV+ fitted at more than 2.5 bar:

In addition, the response with OEM plastic-piston valves is significantly worse, because they always open "fully" and so vent too much air, which means the turbocharger first has to refill the system when you get back on the throttle. The leakage of the OEM valve makes this even worse, as the turbo can only build pressure more slowly. On tuned vehicles this behaviour is all the more pronounced, because the higher boost pressure means even more air is lost and the OEM valves wear even faster, becoming "leakier".
The DV+, on the other hand, seals 100%, even after years. The main piston spring also significantly improves response. Please also read "Running the DV+ without the main piston spring". |
| Troubleshooting |
Some customers report problems with their vehicles after fitting the DV+. These range from loss of power to uneven power delivery or stored fault codes. There are also many false claims circulating in various forums that are simply not backed up – on the contrary, we have disproved them in lab tests. As GFB is now an OEM supplier for the KTM X-Bow and the valves have been tested extensively by KTM’s engineers, this is proof that the valves work flawlessly!
- Stored fault codes
On some vehicles (depending on the version of the original software) faults are occasionally stored in the ECU memory. However, these are only so-called "soft codes", which do not switch on a warning light on the dash. Because of the different (better!) way the DV+ works, the ECU detects this and stores a fault. This is completely harmless and can be ignored! The valve still seals and works perfectly.
If the fault is unwanted, the main piston spring can be removed and the fault will disappear too, because the DV+ then works in the same way as the OEM valve (opening 100%). However, you then lose the advantage of better response on gear changes. Be sure to read "Running the DV+ without the main piston spring".
- Reduced performance
Because of the inherent leak of the OEM valves, depending on the tune it can happen that, after fitting the DV+, the now sealed system results in higher boost pressure under load, as the turbocharger no longer has to make up for the leak in the charge-air system. Pressure limits (or other limits) are then exceeded and the ECU opens the valve under load or retards the ignition, which leads to a loss of power. This is rather rare, however, depends heavily on the other components fitted to the vehicle and can be fixed by the tuner revising the map.
- Loss of boost
Read more here: Click
Please check first: If you are experiencing problems with insufficient boost pressure, please make sure that a) the valve/piston is mechanically sound. See this guide. Even a piston that has been dropped on the floor during installation can cause problems and make the piston stick in operation, because of the small clearance between piston and body and any deformation from the impact. b) the (thin, long) spring supplied with the DV+ is used. The spring from the OEM valve must not be reused, as the DV+ will then not hold boost.
- False claims in forums: "rub marks" on the piston affect sealing
Operating the valve inevitably causes slight "rub marks" on the brass piston, as diverter valves (unlike engines) do not use piston rings. These rub marks are normal for piston valves and also occur on products from other manufacturers – you just don’t see the piston there, because it is enclosed in a housing (unlike the DV+, for example) and the valve is not normally taken apart. They in no way affect the function or sealing of the valve – we have tested this several times in the lab!
- Noises when the valve operates
Depending on the modifications made to the vehicle (e.g. intake), there may be noises when the valve opens or closes. These range from a "chirp" to other noises. A slight "chirp" is normal with piston valves. If other noises occur and you find them unpleasant, we recommend removing the main piston spring. We would expressly point out, however, that these noises do not cause the valve to malfunction. Please also read the item "DV+ T9351 Tech Tip".
All of the points above can occur, but do not have to. This depends very much on the modifications to the vehicle and the version of the ECU software!
If you still have problems that are not covered by the points above, we need the following information to analyse the problem:
- Exact vehicle details: make, model, engine
- Has the car been remapped, or are there any other engine modifications?
- The exact fault codes from the diagnosis (if carried out)
- Can the piston be moved up and down in its bore without noticeable resistance?
- How many kilometres was the valve fitted for, and when did the problems occur?
- How does the problem show itself? Does it occur in a particular rev range (if so, which)?
|
| Testing the sealing of the DV+ compared with the OEM valve |
This guide is aimed mainly at dealers and technically minded people who would like to try a leak test against the OEM valve themselves.
A note first: There will never be a 100% leak-free piston valve – every piston valve has a slight leak, but it is far smaller than that of the OEM valve and the turbocharger can easily compensate for it. This is the case with piston valves from every manufacturer.
Only diaphragm valves are 100% leak-free, but they cannot withstand high boost pressures and tear quickly.
Check first
If you are experiencing problems with insufficient boost pressure, please make sure that
- the valve/piston is mechanically sound. See this guide. Even a piston that has been dropped on the floor during installation can cause problems and make the piston stick in operation, because of the small clearance between piston and body and any deformation from the impact.
- the (thin, long) spring supplied with the DV+ is used. The spring from the OEM valve must not be reused, as the DV+ will then not hold boost.
Comparison test DV+ vs. OEM valve – in black and white
One log with the OEM valve and another with the DV+ V2: log the N75 duty cycle, boost, engine speed and turbo speed. After the adaptation period, the log with the DV+ will show a much lower N75 duty cycle and turbo speed. The reason for this is that the DV+ seals.
The graphs then show this very clearly.
However, many tuners also run into problems, because the software is calibrated for the leaking OEM valve and the boost rises so quickly (due to the N75 programming) that control limits are exceeded and the ECU opens the valve. We have even had a case where this only happened when the car was driven on the road, but not on the dyno! The reason is that boost rises faster on the road because of the completely different driving style.
It was initially suspected that 2 bar of boost was too high, but we already have several cars (e.g. Golf 7) running 2.2 bar without any problems!
Here is a chart showing the scenario described above:

You can see very clearly that the N75 duty cycle with the DV+ (red curve) is lower than with the OEM valve (purple curve). This clearly indicates the leak in the OEM valve.
When the boost then drops because a control limit has been exceeded and the ECU opens the valve, the ECU compensates and slowly increases the N75 duty cycle again to feel its way back towards the control limit.
As mentioned, though, this scenario was only observed on the road. On the dyno there was no drop in boost! So the boost of more than 2 bar cannot have been too high for the DV+.
The solution is for the tuner to adapt the software.
Comparison test DV+ vs. OEM valve – visual
To demonstrate the difference in sealing between the OEM valve and the DV+ to customers in a simple way, we recommend the following:
With a test setup using e.g. a remote mount (as on K04 vehicles), fit a large-capacity balloon to the outlet side and carry out the test with the OEM valve and with the DV+.
Alternatively, this can also be done on the dyno and shows very clearly that the DV+ seals far better than the OEM valve. |
| Adjusting the spring preload on pressure-controlled DV+, Deceptor Pro II, Mach 2 and Respons TMS valves |
Note: No adjustment is required on any DV+ valve (except the DVX) that is used together with a solenoid valve unit (= electronic actuation). This description applies to, among others, the Deceptor Pro II, Mach 2 and Respons TMS ranges as well as the pressure-controlled DV+ valves and the DVX series.
The small stainless steel screw on top of the valve adjusts the piston spring preload. Winding the screw in increases the spring preload, winding it out makes it softer. The spring preload only controls the opening time of the valve on throttle lift-off (gear changes) and has nothing to do with how well the valve seals, as all GFB valves hold their seal by pressure and counter-pressure. This is in contrast to valves from other manufacturers, which need different spring kits with different spring rates for different boost levels to ensure they seal. This is not the case with any GFB valve! This means GFB valves seal regardless of the boost pressure you run, without any further adjustment of the screw!
Aim of the adjustment: you need to find a spring preload setting at which the valve opens just far enough (i.e. vents just enough air) to prevent compressor surge (where the turbo’s compressor wheel is slowed down by pressure backing up in the charge-air system on throttle lift-off), but without letting so much pressure escape on lift-off that the turbo has to build the pressure in the system up again when you get back on the throttle. The optimum setting therefore gives you the best possible throttle response.
At the start of the adjustment process, set the spring to the lowest preload, i.e. wind the screw out as far as it will go. Do not wind the screw out more than 3 mm from the valve, otherwise it could fall out while driving.
The final setting can now be found by trial and error on a test drive. The softest setting will probably let too much air escape from the system on throttle lift-off. So wind the screw in one full turn after each drive. This lets you gradually approach the point of turbo surge. At some point the engine will hesitate on gear changes or a kind of "chirping" or fluttering noise will appear, because the turbo has started to surge. In that case, back the screw out by one turn again to avoid the surge (= "chirping") while still keeping the optimum pressure in the system on lift-off. |
| Checking the DV+ for mechanical faults |
The DV+ is a mechanical part and can be checked for a suspected fault simply by inspecting its components. Proceed as follows:
- Inspect the piston and make sure the red rubber face is undamaged. The small 2 mm hole in the top of the piston must be clear. Any rub marks on the outside of the piston are completely normal for piston valves and do not indicate a fault. They appear within the first few weeks of use and stop increasing after a certain point.
- Inspect the body and how the piston runs in the body: Remove any oil residue, insert the piston into the body and make sure it slides up and down freely without resistance and turns freely (NOTE: because of the fit tolerance in the hundredths of a millimetre, the piston can be a little difficult to insert at first, but once it is a certain depth into the bore it should slide freely). Now let the piston slide all the way down into the body and make sure it falls out of the body when you tip the valve over (CAUTION: Only let the piston drop into your hand, as dropping it on the floor may mean the precise fit to hundredths of a millimetre can no longer be guaranteed!!)
- Inspect the orange O-ring on the black pin (the so-called plunger) that seals the rear opening of the body when installed. Make sure it is not damaged. It may be slightly discoloured, but this is normal.
- Inspect the plunger for wear of the coating. There should be no wear anywhere (worn areas would show as silver). If there is, please contact us and attach a few photos.
- Make absolutely sure that you use the plunger spring supplied with the DV+ (long, thin spring) and not the one fitted to the OEM valve! Otherwise this can lead to a loss of boost on tuned vehicles. The OEM spring is approx. 42-44 mm long and the DV+ spring is 35 mm.
If all of the points above are met, the DV+ must work. The DV+ technology has been proven thousands of times over and is also offered by KTM as part of its performance portfolio for X-Bow vehicles with the VAG 2.0 TFSI engine.
How to inspect the DV+
- Inspect the piston and make sure the silicone face seal is undamaged, and that the small 2 mm hole through the face is clear. It is normal to see some vertical rub marks on the piston; these occur very early on but do not progress any further after about a week of operation.
- Inspect the DV+ body and piston – wipe off any oil, then insert the piston into the body and make sure it slides and spins smoothly and freely without binding at any point (it can be difficult to start in the bore initially because of the close fit, but once in it should slide freely). Push it all the way into the body and make sure it still falls out when you tip it up (don’t drop the piston though!!).
- Inspect the orange O-ring on the tip of the plunger and make sure it’s not damaged (it may be discoloured, that’s normal).
- Inspect the plunger for signs of damage or wear to the black plating. If it is hitting something it shouldn’t be hitting, there will be tell-tale silver marks where the plating is worn through.
- Make sure the GFB-supplied plunger spring is used; it can be identified by its length, which is 35 mm. The factory solenoid spring is approximately 42-44 mm.
If there is nothing obviously wrong in the checks above, it is worth trying the DV+ without the main piston spring, as this will replicate the factory diverter operation, to see if the behaviour changes. |
| TÜV approval and registration? |
The legal text reads as follows:
Under §19 of the German Road Traffic Licensing Regulations (StVZO), a vehicle’s operating permit (Betriebserlaubnis, BE) remains valid until the vehicle is taken off the road, and only lapses if modifications are made by which:
1. the vehicle type approved in the operating permit (BE) is changed
2. a danger to other road users is to be expected
3. the exhaust emissions or noise characteristics are made worse.
Depending on the type of valve, it may only be operated in certain positions:
- Valves that offer an adjustment mechanism for venting charge air to atmosphere (blow-off valves with an adjustable vented amount from 0 to 100%: e.g. Deceptor Pro II, Respons and DVX range)
- Because valves that vent to atmosphere release oil vapour together with the charge air, and also change the noise characteristics of the vehicle, they are not approved for road use.
- If the valve allows the amount of charge air vented to atmosphere to be adjusted, it may only be operated in the 100% recirculating setting on public roads.
- Valves that vent all or part of the air to atmosphere and are not adjustable (e.g. VTA, SV52, Hybrid TMS, etc.)
- This type of valve may only be used in motorsport, because valves that vent to atmosphere release oil vapour together with the charge air and also change the noise characteristics of the vehicle.
- Valves that are pure diverter valves (i.e. recirculate 100% of the air = same function as the OEM valve: e.g. DV+, Mach 2)
- According to the legal text above, these valves do not need to be registered, as none of the points listed there apply.
|
| How long is the warranty period? |
30-year GFB warranty
All products bought from us come with the 30-year GFB warranty. This warranty is in addition to your statutory rights and is valid throughout Europe. The warranty covers defects in materials and workmanship that existed at the time of purchase. In the event of a valid claim, we will remedy the defect by repair, replacement or a refund of the reduced value, at our discretion. The warranty only applies if the product has been installed in compliance with all relevant regulations, including the product’s safety instructions and fitting instructions.
Excluded from the warranty are
- any damage caused by improper handling, accidents or failure to follow the instructions for use.
- any damage resulting from use exclusively in motorsport.
- any damage caused by fitting our products to vehicles for which we do not list the product in question in our online catalogue.
Valid defects must be reported within four weeks of becoming aware of them, together with the original proof of purchase.
The warranty period is not extended after a warranty repair or replacement. Installation costs and/or consequential costs are not reimbursed.
The warrantor is GFB Australia, No 2 Norman Street, Peakhurst NSW Australia 2210.
In addition to this warranty, you are entitled to your statutory warranty rights. These are not restricted by making a claim under the warranty and can be asserted against GFB Deutschland – owner Christian Maier, Bergstraße 20, 91074 Herzogenaurach, Germany, if the item was bought from GFB Deutschland or one of its dealers.
You can also find information about the warranty on the manufacturer’s website.
Herzogenaurach, March 2019 |
| How the DV+ works |
As described under "Self-regulation of GFB valves", all versions of the DV+ are self-regulating too. Unlike pressure-controlled valves, electronically controlled valves no longer have a pressure control line, so the boost pressure behind the DV+ piston flows from below through a small hole into the piston. Because the area on which the boost pressure can act inside the piston is approx. 25% larger than the rubber-faced underside, the force from above is also greater and the piston stays closed, no matter how much boost is applied. While other manufacturers offer different spring kits for different boost levels, the clever design of the DV+ makes these completely unnecessary. The result is "self-regulation" regardless of the boost pressure applied.
So the first step is
- Under load (throttle open = accelerating), boost pressure flows into the piston
The electronic control unit pushes down the black pin supplied with the DV+, which has an O-ring seal at its lower end (the so-called "pilot"). This seals off the space behind the piston at the top = the pressure in the piston cannot escape and a force builds up that pushes the piston down. In this way the piston seals the system.
So the second step is
- The ECU sends the signal to the valve’s control unit to close the system
Now comes the first gear change. The driver lifts off the throttle, the ECU closes the throttle body and triggers the diverter valve to open. As the control unit pulls its metal pin upwards to open the valve, the pressure in the piston can now also push the "pilot" upwards, the pressure can escape upwards out of the piston and the piston opens. The air is fed back into the system through the side ports on the angled faces of the DV+ body.
So the third step is
- The ECU gives the signal to open, the pilot is pushed upwards, the pressure behind the piston can escape and the valve opens
|
|