The DV+ is a mechanical part and can be checked for a suspected fault simply by inspecting its components. Proceed as follows:
- Inspect the piston and make sure the red rubber face is undamaged. The small 2 mm hole in the top of the piston must be clear. Any rub marks on the outside of the piston are completely normal for piston valves and do not indicate a fault. They appear within the first few weeks of use and stop increasing after a certain point.
- Inspect the body and how the piston runs in the body: Remove any oil residue, insert the piston into the body and make sure it slides up and down freely without resistance and turns freely (NOTE: because of the fit tolerance in the hundredths of a millimetre, the piston can be a little difficult to insert at first, but once it is a certain depth into the bore it should slide freely). Now let the piston slide all the way down into the body and make sure it falls out of the body when you tip the valve over (CAUTION: Only let the piston drop into your hand, as dropping it on the floor may mean the precise fit to hundredths of a millimetre can no longer be guaranteed!!)
- Inspect the orange O-ring on the black pin (the so-called plunger) that seals the rear opening of the body when installed. Make sure it is not damaged. It may be slightly discoloured, but this is normal.
- Inspect the plunger for wear of the coating. There should be no wear anywhere (worn areas would show as silver). If there is, please contact us and attach a few photos.
- Make absolutely sure that you use the plunger spring supplied with the DV+ (long, thin spring) and not the one fitted to the OEM valve! Otherwise this can lead to a loss of boost on tuned vehicles. The OEM spring is approx. 42-44 mm long and the DV+ spring is 35 mm.
If all of the points above are met, the DV+ must work. The DV+ technology has been proven thousands of times over and is also offered by KTM as part of its performance portfolio for X-Bow vehicles with the VAG 2.0 TFSI engine.
How to inspect the DV+
- Inspect the piston and make sure the silicone face seal is undamaged, and that the small 2 mm hole through the face is clear. It is normal to see some vertical rub marks on the piston; these occur very early on but do not progress any further after about a week of operation.
- Inspect the DV+ body and piston – wipe off any oil, then insert the piston into the body and make sure it slides and spins smoothly and freely without binding at any point (it can be difficult to start in the bore initially because of the close fit, but once in it should slide freely). Push it all the way into the body and make sure it still falls out when you tip it up (don’t drop the piston though!!).
- Inspect the orange O-ring on the tip of the plunger and make sure it’s not damaged (it may be discoloured, that’s normal).
- Inspect the plunger for signs of damage or wear to the black plating. If it is hitting something it shouldn’t be hitting, there will be tell-tale silver marks where the plating is worn through.
- Make sure the GFB-supplied plunger spring is used; it can be identified by its length, which is 35 mm. The factory solenoid spring is approximately 42-44 mm.
If there is nothing obviously wrong in the checks above, it is worth trying the DV+ without the main piston spring, as this will replicate the factory diverter operation, to see if the behaviour changes. |