As described under "Self-regulation of GFB valves", all versions of the DV+ are self-regulating too. Unlike pressure-controlled valves, electronically controlled valves no longer have a pressure control line, so the boost pressure behind the DV+ piston flows from below through a small hole into the piston. Because the area on which the boost pressure can act inside the piston is approx. 25% larger than the rubber-faced underside, the force from above is also greater and the piston stays closed, no matter how much boost is applied. While other manufacturers offer different spring kits for different boost levels, the clever design of the DV+ makes these completely unnecessary. The result is "self-regulation" regardless of the boost pressure applied.
So the first step is
- Under load (throttle open = accelerating), boost pressure flows into the piston
The electronic control unit pushes down the black pin supplied with the DV+, which has an O-ring seal at its lower end (the so-called "pilot"). This seals off the space behind the piston at the top = the pressure in the piston cannot escape and a force builds up that pushes the piston down. In this way the piston seals the system.
So the second step is
- The ECU sends the signal to the valve’s control unit to close the system
Now comes the first gear change. The driver lifts off the throttle, the ECU closes the throttle body and triggers the diverter valve to open. As the control unit pulls its metal pin upwards to open the valve, the pressure in the piston can now also push the "pilot" upwards, the pressure can escape upwards out of the piston and the piston opens. The air is fed back into the system through the side ports on the angled faces of the DV+ body.
So the third step is
- The ECU gives the signal to open, the pilot is pushed upwards, the pressure behind the piston can escape and the valve opens
|